| MRC | Criteria | Characteristic | 
|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED | 
| ABJT | TERMINAL LENGTH | 0.375 INCHES NOMINAL | 
| ADAQ | BODY LENGTH | 0.043 INCHES NOMINAL | 
| ADAR | BODY OUTSIDE DIAMETER | 0.043 INCHES NOMINAL | 
| AEBT | TERMINAL DIAMETER | 0.004 INCHES NOMINAL | 
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS | 
| AEHZ | MAXIMUM OPERATING TEMP | 300.0 DEG CELSIUS | 
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 4.0 | 
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.4 | 
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.40 | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 200.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 30.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 300.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT | 
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 90.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.7 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 115.4 OHMS 9TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 16.1 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 23.5 OHMS 10TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.05 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 336.4 OHMS 8TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 368.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.8 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 67.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT | 
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 721.6 OHMS 7TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.7 TO 15.7 4TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.5 TO 17.5 3RD RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.3 TO 18.3 5TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.6 TO 20.6 6TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -21.4 TO 21.4 2ND RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -22.5 TO 22.5 7TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -24.2 TO 24.2 8TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -26.1 TO 26.1 1ST RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -26.5 TO 26.5 9TH RESISTANCE-TEMPERATURE POINT | 
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -29.8 TO 29.8 10TH RESISTANCE-TEMPERATURE POINT | 
| AKNA | INCLOSURE TYPE | ENCAPSULATED | 
| CBME | CUBIC MEASURE | 0.00005 CUBIC INCHES | 
| CQWD | ZERO POWER RESISTANCE | 20.000 KILOHMS | 
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -15.0 TO 15.0 | 
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 | 
| SFTT | SURFACE TREATMENT | SOLDER TERMINAL | 
| STYL | STYLE DESIGNATOR | SEALED OR COATED BEAD | 
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |