| MRC | Criteria | Characteristic |
|---|
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0/14.0 5TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 6TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0/20.0 7TH RESISTANCE-TEMPERATURE POINT |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | ZERO POWER RESISTANCE | 330.000 OHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/10.0 |
| STYL | STYLE DESIGNATOR | SPHERICAL |
| TEST | TEST DATA DOCUMENT | 00752-361254 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| ADAR | BODY OUTSIDE DIAMETER | 0.180 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.200 INCHES MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.013 INCHES NOMINAL |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 350.00 MILLIWATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 16.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.5 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -19.80 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.9 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 133.6 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 16.5 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 30.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 60.7 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 940.5 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0/14.0 2ND RESISTANCE-TEMPERATURE POINT |