| MRC | Criteria | Characteristic |
|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 12.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 0.625 INCHES MINIMUM AND 0.687 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.656 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.250 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.095 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.0201 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 232.0 DEG CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 2.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.8 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 105.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 145.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 15.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 175.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 205.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 225.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 45.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 65.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 85.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.093 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.907 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 130.66 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 22.72 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 224.76 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.53 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 416.59 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.994 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 659.9 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 94.31 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | ZERO POWER RESISTANCE | 15.000 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -2.0/2.0 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| STYL | STYLE DESIGNATOR | BEAD IN CAN |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |