| MRC | Criteria | Characteristic |
|---|
| ABHP | OVERALL LENGTH | 6.195 INCHES NOMINAL |
| ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 5.570 INCHES NOMINAL |
| ADAT | BODY WIDTH | 3.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 1.500 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 6.320 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.500 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AGAV | END ITEM IDENTIFICATION | OL-170 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT 1ST FUNCTION |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD 2ND FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD INPUT 1ST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 THREADED STUD OUTPUT 2ND FUNCTION |
| CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 230.0 VOLTS AT SEA LEVEL |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 800.0 VOLTS AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |