| MRC | Criteria | Characteristic |
|---|
| ADAT | BODY WIDTH | 16.000 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 17.280 INCHES NOMINAL |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | ENCASED |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CRST | BODY SURFACE TREATMENT | TIN |
| CTJS | UNPACKAGED UNIT WEIGHT | 0.500 POUNDS NOMINAL |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.15 AND 0.10 AND 0.5 AND 1.0 AND 100.0 AND 1000.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| ABHP | OVERALL LENGTH | 31.186 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 5.750 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 28.000 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 25.0 AND 60.060.0 AND 60.0 AND 60.0 AND 60.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB,SOLDER LUG INPUT 1ST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 14.000 INCHES NOMINAL |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 26 UNTHREADED HOLE |
| CBBL | FEATURES PROVIDED | SHOCK RESISTANT AND MOISTURE RESISTANT |
| CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 2.5 KILOVOLTS AT SEA LEVEL |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 2.2 KILOVOLTS AT SEA LEVEL |