| MRC | Criteria | Characteristic |
|---|
| THSD | Thread Series Designator | UNC |
| AKPX | Pole Quantity | 3 |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
| CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES AC ALL LOCATIONS |
| PKWT | Unpackaged Unit Weight | 12.750 OUNCES |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
| TTQY | Terminal Type And Quantity | 6 THREADED STUD |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| CPRP | Ultimate Trip Time Per Pole In Seconds | 0.600 MINIMUM ALL LOCATIONS AND 2.000 MAXIMUM ALL LOCATIONS |
| CSSX | Switch Current Rating And Type In Amps | 2.5 AC |
| AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
| CPRQ | Reset Method | MANUAL |
| CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| ADAT | Body Width | 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM |
| CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
| CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| ADTV | Case Material | METAL |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| AJWX | Mounting Surface To Terminal End Distance | 2.539 INCHES MINIMUM AND 2.683 INCHES MAXIMUM |
| ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
| APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
| AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CQSM | Switch Location And Position Designation | EXTERNAL AT POLE ONE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.020 MINIMUM AT 500 PCT ALL LOCATIONS AND 0.070 MAXIMUM AT 500 PCT ALL LOCATIONS |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| CRTK | Switch Terminal Type | TURRET |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
| CPRW | Actuator Function | TRIP-RESET |
| CMLP | Thread Quantity Per Inch | 32 |
| CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |