| MRC | Criteria | Characteristic |
|---|
| AAJE | THREAD PITCH DIAMETERS | 0.3503 TO 0.3537 INCHES |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.875 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
| AEFS | NONTURN DEVICE DIAMETER | 0.250 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 3 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC AND 20.0 AMPERES DC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | UNDERVOLTAGE SECOND LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 18.0 DC MINIMUM SECOND LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS AND TIME DELAY SECOND LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP SECOND LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.080 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| FEAT | SPECIAL FEATURES | RELAY TRIP COIL AT POLE 2 RATED 250 MILLIAMPERE NOMINAL |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |