| MRC | Criteria | Characteristic |
|---|
| AAJD | THREAD CLASS | 2A 2ND MOUNTING FACILITY |
| AAJD | THREAD CLASS | 2B 1ST MOUNTING FACILITY |
| AASA | THREAD LENGTH | 0.375 INCHES NOMINAL 2ND MOUNTING FACILITY |
| ABHP | OVERALL LENGTH | 12.190 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 3.250 INCHES NOMINAL |
| AFBH | INDIVIDUAL SECTION QUANTITY | 12 |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL 1ST MOUNTING FACILITY |
| AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.000 INCHES NOMINAL 1ST MOUNTING FACILITY |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.180 INCHES NOMINAL 1ST MOUNTING FACILITY |
| AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
| AXGY | MOUNTING METHOD | BRACKET 1ST MOUNTING FACILITY AND THREADED HOLE 1ST MOUNTING FACILITY |
| AXGY | MOUNTING METHOD | THREADED BUSHING 2ND MOUNTING FACILITY |
| CBBL | FEATURES PROVIDED | ACTUATOR KNOB |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES 1ST MOUNTING FACILITY |
| CQJX | NOMINAL THREAD SIZE | 0.625 INCHES 2ND MOUNTING FACILITY |
| CQMK | CONTACT VOLTAGE RATING IN VOLTS | 125.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| CQMK | CONTACT VOLTAGE RATING IN VOLTS | 355.0 DC AT SEA LEVEL |
| CQMK | CONTACT VOLTAGE RATING IN VOLTS | 500.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE 1ST MOUNTING FACILITY |
| CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 4 SINGLE ACTUATOR |
| CSCF | TERMINAL TYPE | SCREW |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 10TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 11TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 12TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 3RD SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 4TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 5TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 6TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 7TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 8TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 9TH SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 1ST SECTION PERIPHERY |
| CSHW | CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS 2ND SECTION PERIPHERY |
| CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
| CTHF | CONTACT LOAD CURRENT RATING | 0.4 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
| CTHF | CONTACT LOAD CURRENT RATING | 20.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | TAP,CIRCUIT SELECTOR |
| THSD | THREAD SERIES DESIGNATOR | UNEF 2ND MOUNTING FACILITY |
| THSD | THREAD SERIES DESIGNATOR | UNF 1ST MOUNTING FACILITY |