| MRC | Criteria | Characteristic |
|---|
| AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
| AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
| ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 6.230 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
| ADTV | CASE MATERIAL | PLASTIC |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
| AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | 62.565 CUBIC INCHES |
| CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CRXH | TIME DELAY | 1.50 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 15.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 480.0 AC |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 125.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
| THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 SCREW ALL FUNCTIONS |