| MRC | Criteria | Characteristic |
|---|
| ABHP | OVERALL LENGTH | 3.730 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.240 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.677 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 2.297 INCHES MINIMUM AND 2.485 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.150 INCHES NOMINAL |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.213 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.223 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL OR 400.0 NOMINAL |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES AC SINGLE WINDING |
| CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC AND 28.0 DC |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |