| MRC | Criteria | Characteristic |
|---|
| AFZX | THIRD BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 3.640 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAC | FIRST BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| CQBC | MINIMUM TENSILE STRENGTH | 1200 POUNDS PER SQUARE INCH |
| HUES | COLOR | BLACK |
| STYL | STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJH | TEMP RATING | -55.0 DEG CELSIUS |
| AFZU | MAIN BODY INSIDE DIAMETER | 1.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZU | MAIN BODY INSIDE DIAMETER | 2.190 INCHES MINIMUM AS SUPPLIED |
| AFZY | FOURTH BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| AFZZ | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 4.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAD | SECOND BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAE | THIRD BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAF | FOURTH BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATT | MATERIAL | PLASTIC,POLYOLEFIN,RT-1304,RAYCHEM CORP |
| UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 225.0 VOLTS PER MIL /0.001 INCH |
| ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
| AFZV | FIRST BRANCH INSIDE DIAMETER | 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZV | FIRST BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| AFZW | SECOND BRANCH INSIDE DIAMETER | 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZW | SECOND BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| AFZX | THIRD BRANCH INSIDE DIAMETER | 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| AGAB | MAIN BODY WALL THICKNESS | 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 4.270 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| FLEX | FLEXIBILITY | FLEXIBLE |