| MRC | Criteria | Characteristic |
|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
| AAJD | THREAD CLASS | 2A FIRST FLANGE ALL CONNECTION FACILITIES |
| AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| AGAV | END ITEM IDENTIFICATION | ADVANCED AIR TRAFFIC CONTROL AND LAND SYSTEM (ATCALS) 404L. |
| AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
| AHSF | FLANGE QUANTITY | 2 |
| AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
| AHSX | FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM SECOND FLANGE AND 1.256 INCHES MAXIMUM SECOND FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.628 INCHES MINIMUM SECOND FLANGE AND 0.631 INCHES MAXIMUM SECOND FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
| AHTD | FLANGE DEPTH | 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
| AHTX | INSERTION LOSS IN DECIBELS | 0.09 |
| CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE ALL CONNECTION FACILITIES |
| CQGM | MAXIMUM OPERATING PRESSURE | 40.0 POUNDS PER SQUARE INCH GAGE |
| CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
| CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
| CTFD | WAVEGUIDE LENGTH | 1.500 FEET NOMINAL |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
| MATT | MATERIAL | ALUMINUM ALLOY ALL FLANGE |
| PMLC | PRECIOUS MATERIAL AND LOCATION | FLANGE SURFACE AND TUBING SURFACE SILVER |
| PRMT | PRECIOUS MATERIAL | SILVER |
| SFTT | SURFACE TREATMENT | CHROMATE ALL FLANGE OUTSIDE SURFACES |
| STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
| THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
| ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |