| MRC | Criteria | Characteristic |
|---|
| CRFH | WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
| CRLB | WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
| CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
| CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| CTCJ | FLANGE STYLE | COVER TYPE FIFTH FLANGE |
| CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
| CTCJ | FLANGE STYLE | COVER TYPE FOURTH FLANGE |
| CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
| CTCJ | FLANGE STYLE | COVER TYPE THIRD FLANGE |
| MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
| ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
| AHSF | FLANGE QUANTITY | 6 |
| AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FIFTH FLANGE AND 0.707 INCHES MAXIMUM FIFTH FLANGE |
| AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FIRST FLANGE AND 0.707 INCHES MAXIMUM FIRST FLANGE |
| AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM FOURTH FLANGE AND 0.707 INCHES MAXIMUM FOURTH FLANGE |
| AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM SECOND FLANGE AND 0.707 INCHES MAXIMUM SECOND FLANGE |
| AHSX | FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM THIRD FLANGE AND 0.707 INCHES MAXIMUM THIRD FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FIFTH FLANGE AND 0.396 INCHES MAXIMUM FIFTH FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FIRST FLANGE AND 0.396 INCHES MAXIMUM FIRST FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM FOURTH FLANGE AND 0.396 INCHES MAXIMUM FOURTH FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM SECOND FLANGE AND 0.396 INCHES MAXIMUM SECOND FLANGE |
| AHSY | FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM THIRD FLANGE AND 0.396 INCHES MAXIMUM THIRD FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FIFTH FLANGE AND 1.328 INCHES MAXIMUM FIFTH FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM FOURTH FLANGE AND 1.328 INCHES MAXIMUM FOURTH FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
| AHSZ | FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM THIRD FLANGE AND 1.328 INCHES MAXIMUM THIRD FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIFTH FLANGE AND 1.328 INCHES MAXIMUM FIFTH FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIRST FLANGE AND 1.328 INCHES MAXIMUM FIRST FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FOURTH FLANGE AND 1.328 INCHES MAXIMUM FOURTH FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM SECOND FLANGE AND 1.328 INCHES MAXIMUM SECOND FLANGE |
| AHTA | FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM THIRD FLANGE AND 1.328 INCHES MAXIMUM THIRD FLANGE |
| AHTD | FLANGE DEPTH | 0.090 INCHES NOMINAL FIFTH FLANGE |
| AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM FIRST FLANGE AND 0.328 INCHES MAXIMUM FIRST FLANGE |
| AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM FOURTH FLANGE AND 0.328 INCHES MAXIMUM FOURTH FLANGE |
| AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM SECOND FLANGE AND 0.328 INCHES MAXIMUM SECOND FLANGE |
| AHTD | FLANGE DEPTH | 0.298 INCHES MINIMUM THIRD FLANGE AND 0.328 INCHES MAXIMUM THIRD FLANGE |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.118 INCHES MINIMUM SIXTH FLANGE ALL CONNECTION FACILITIES AND 0.123 INCHES MAXIMUM SIXTH FLANGE ALL CONNECTION FACILITIES |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.142 INCHES MINIMUM FIFTH FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIFTH FLANGE ALL CONNECTION FACILITIES |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FOURTH FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FOURTH FLANGE ALL CONNECTION FACILITIES |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM THIRD FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM THIRD FLANGE ALL CONNECTION FACILITIES |
| AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 |
| AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
| CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |