Whether you are in the market for NSN parts, military and defense parts, aerospace parts, or other similar product solutions, Buy Military Fasteners is your one-stop shop with an expansive selection tracing back to premier manufacturers and entities that we trust. Thank you for taking an interest in part number FL-S62-1 ITEM 1, a United States Coast Guard Aircraft Repair And Supply Center item that is listed alongside the description “Transformer Power” and the NSN 6120011024845. As part number FL-S62-1 ITEM 1 is ready for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with crucial details such as your target price and expected shipping time frame, that way we can best customize a solution that caters to your unique requirements and constraints alike.
Note: We Will Not Share Your Information with Any Third Parties.
As customers explore our vast selection, they can take advantage of services like our CAGE Code search features or database filters to quickly locate products of interest for purchase. For example, part number FL-S62-1 ITEM 1 is listed alongside the NSN 6120-01-102-4845, meaning that it also belongs to FSC 6120 Transformers Distribution and Power Station. With this in mind, kick off procurement with us today with assurance that we can even fulfill your most difficult needs.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6120-01-102-4845 Item PartTypeName: TRANSFORMER,POWER | 6120 | 011024845 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| FL-S62-1 ITEM 1 | 2 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | 0.562 INCHES NOMINAL SINGLE GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 12.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 10.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 14.750 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | SHORE POWER ISOLATION TRANSFORMER ONBOARD 41 FT UTB CG VESSELS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 62.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| CRMJ | WINDING POWER RATING | 7.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| FEAT | SPECIAL FEATURES | 5TH WIRE LEAD IS GROUND |
| TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |